Home ➔ Vacuum Pumps ➔ Diffusion Pumps ➔ nHT Series
The optimised pumping speed and stable high throughput is ideal for the critical Coating, Metallurgy, Heat Treatment and R & D applications.
The smart temperature control and on board sensors ensure minimum load with longer lifetime for heaters and oil. The non-wear components and easy-change heater cartridges ensure extended intervals between service and maintenance.
The Energy Efficiency Controller enables ease of use and operating convenience along with effective monitoring with USB and Ethernet interface. The innovative heating design provides a faster warm up time and enables up to 30% energy savings.
nEXT has been designed to combine all the latest technological advances in turbomolecular pumps offering pump sizes of 55, 85, 240, 300, 400, 730, 925 and 1250 l/s pumping speeds for Nitrogen these pumps provide end-user serviceability and deliver a truly class leading product.
nHT10 | nHT16 | nHT20 | nHT32 | nHT35 | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ANSI | ISO | ANSI | ISO | ANSI | ISO | ANSI | ISO | ANSI | ISO | ||
Inlet connection | 10˝ ANSI | 320 ISO-K | 16˝ ANSI | 500 ISO-K | 20˝ ANS | 630 ISO-K | 32” ANSI | 800 ISO-F | 35˝ ANSI | 1000 ISO-F | |
Backing connection | 2˝ ANSI | 63 ISO-K | 3” ANSI | 100 ISO-K | 4˝ ANSI | 160 ISO-K | 6” ANSI | 200 ISO-K | 6” ANSI | 200 ISO-K | |
Pumping speed* Nitrogen <10-4 mbar | l/s | 3,000 | 6,800 | 10,000 | 21,000 | 30,000 | |||||
Pumping speed Argon <10-4 mbar | l/s | 2,750 | 6,350 | 9,000 | 18,000 | 26,000 | |||||
Pumping speed Helium <10-4 mbar | l/s | 4,500 | 9,500 | 17,000 | 30,000 | 42,000 | |||||
Gas throughput | mbar l/s | 8 | 11 | 17 | 36 | 36 | |||||
Operating range | mbar | < 10-1 to 10-7 | < 10-1 to 10-7 | < 10-1 to 10-7 | <10‐2 to 10‐7 | < 10-2 to 10-7 | |||||
Ultimate pressure (Edwards 704) | mbar | < 5 x 10-7 | < 5 x 10-7 | < 5 x 10-7 | < 10‐6 | < 10-6 | |||||
Critical backing pressure (Edwards 704) | mbar | 5 x 10-1 | 5 x 10-1 | 5 x 10-1 | 5 x 10-1 | 5 x 10-1 | |||||
Heating power | kW | 3.6 | 7.2 | 10.8 | 21.6 | 21.6 | |||||
Heating cartridges | qty | 3 | 6 | 9 | 18 | 18 | |||||
Warm-up period | min | < 15 | < 15 | < 25 | < 25 | < 25 | |||||
Weight | kg | 105 | 185 | 210 | 570 | 720 | |||||
Recommended oil | Edwards 704 | ||||||||||
Oil | l | 3.0-4.0 | 3.5-4.5 | 5.5-7.0 | 9.0-11.0 | 9.0-11.0 | |||||
Recommended holding pump | E2M40 | E2M40 | E2M40 | E2M80 | E2M80 | ||||||
Recommended backing pump | nES200, E2M80, EDS200, EH1200 | nES200, E2M175, EDS200, EH1200 | nES300, E2M175, EDS300, EH1200 | nES630, E2M275, GXS450, EH2600 | nES630, E2M275, GXS450, EH2600 | ||||||
* Measures as per DIN 28 427 |
+41 (0)32 926 26 06